Sale!

Philips M1013A IntelliVue G1 Gas Module

Original price was: $5.150.Current price is: $2.399.

The Philips M1013A IntelliVue G1 Gas Module is a medical device that measures respiratory and anesthetic gases, including carbon dioxide (\(CO_{2}\)) and nitrous oxide (\(N_{2}O\)). It works with specific Philips IntelliVue patient monitors and requires manual selection of the anesthetic agent for measurement. The module provides waveform and numerical displays for inspired and end-tidal gas values, as well as calculated MAC values, for monitoring ventilated patients during anesthesia.

Description

Philips M1013A IntelliVue G1 Gas Module

The versatility of IntelliVue Anesthetic Gas Modules can provide measurements of the five most commonly used anesthetic gases, as well as nitrous oxide (N2O) and carbon dioxide (CO2). The IntelliVue G1 gas module measures the single agent selected manually by the clinician,

IntelliVue Gas Modules work in conjunction with Phillips IntelliVue patient monitors to display waveforms for all gasses along with inspiratory and end-tidal numerical values. In addition, the minimal alveolar concentration (MAC) is calculated from the anesthetic agents measured, including N2O.

The IntelliVue gas modules provide real-time clinically solid measurements of:

  • Sevoflurane, Isoflurane, Halothane, Desflurane, and Enflurane.
  • Nitrous oxide (N2O), Carbon dioxide (CO2) and Oxygen (O2).
Philips M1013A IntelliVue G1 Gas Module Features:

  • Quick warm-up time.
  • Rapid response time.
  • Individual alarm limits for each parameter.
  • Automatic zero calibration.
  • Lifetime calibration for easier maintenance.
  • Highly durable solid-state sensor design.Airway respiration rate.
  • Minimal Alveolar Concentration (MAC) values.
Philips M1013A IntelliVue G1 Gas Module Specifications:
  • Compatibility: Philips IntelliVue MP20/30/40/50/60/70/80/90 Patient Monitors (In the U.S. and Canada).
  • Physical Size (H x W x D): 85 x 300 x 232 mm (3.35 x 11.81 x 9.13 inches).
  • Weight: < 4 kg (8.8 lb) net.
  • Units: mmHg, kPa, vol% for all gases (except for CO2, no vol%).
  • Power Requirements:
    • Input: 100 to 240 V ±10 % ac.
    • Frequency: 50/60 Hz.
    • Power consumption: 45 VA max.
The Philips M1013A IntelliVue G1 Gas Module is a medical device that measures respiratory and anesthetic gases, including carbon dioxide (

CO2cap C cap O sub 2

𝐶𝑂2

) and nitrous oxide (

N2Ocap N sub 2 cap O

𝑁2𝑂

). It works with specific Philips IntelliVue patient monitors and requires manual selection of the anesthetic agent for measurement. The module provides waveform and numerical displays for inspired and end-tidal gas values, as well as calculated MAC values, for monitoring ventilated patients during anesthesia. 

Key features and functions 
    • Gas measurement: Measures

      CO2cap C cap O sub 2

      𝐶𝑂2

      ,

      N2Ocap N sub 2 cap O

      𝑁2𝑂

      , and one selected anesthetic agent (Sevoflurane, Isoflurane, Halothane, Desflurane, or Enflurane).

    • Manual agent selection: Unlike the IntelliVue G5 module, the G1 requires the clinician to manually select the anesthetic agent for measurement.
    • Optional fast oxygen (

      O2cap O sub 2

      𝑂2

      ): A fast

      O2cap O sub 2

      𝑂2

      measurement based on paramagnetic technology is an optional feature.

    • Patient monitor integration: Displays waveforms and numerical values on compatible Philips IntelliVue patient monitors, such as the MP20, MP30, MP40, and MP50.
    • MAC value calculation: Calculates the Minimal Alveolar Concentration (MAC) value from the measured anesthetic agents.
  • Performance: Performs automatic zero calibration to maintain accuracy.
  • Compatibility: Works with the IntelliVue MP20/30/40/50/60/70/80/90 patient monitors. 

 